product fiche

- IF YOU HAVE A PROBLEM

 

PROBLEM

 

CAUSE

 

 

REMEDY 0

 

 

 

 

 

Motor does not start.

 

No power supply.

 

Check cable, plug and socket.

 

 

 

Thermal cut-out.

 

Leave to cool.

 

 

 

 

 

Suction force is gradually

 

Nozzle, suction hose or tube

Check for blockage and remove

decreasing.

 

is blocked.

 

it.

 

Cord does not rewind

 

Check that the cord is not

Pull the cord out 2-3m and

fully.

 

twisted or wound unevenly.

push the cord rewind button.

 

 

 

 

 

Vacuum cleaner does

 

Crack or hole in hose.

 

Check hose and replace if

not pick up dirt.

 

 

 

 

required.

 

Low or decreasing

 

Filter is full of dust.

 

Please check filter and, if

suction

 

 

 

 

necessary, clean as illustrated in

 

 

 

 

 

 

the instructions.

 

This Vacuum cleaner is approved the following.

 

 

 

 

 

EMC Directive : 2004/108/EEC

 

 

 

 

 

Low Voltage Directive : 2006/95/EC

 

 

 

 

 

[English]

 

 

 

 

 

 

 

According to Commission Regulation (EU) No 665/2013 and No 666/2013

 

 

 

 

 

 

 

 

 

 

A

Supplier

 

 

Samsung Electronics., Co. Ltd

 

 

 

 

 

 

 

 

 

 

B

Model

 

 

SC43E0

 

SC43Q*

 

SC43T*

 

 

 

 

 

 

 

 

 

 

C

Energy Efficiency Class

 

 

G

 

B

 

 

 

 

 

 

 

 

 

D

Annual Energy Consumption (kWh/yr)

 

61.0

 

34.0

 

 

 

 

 

 

 

 

 

E

Carpet Cleaning Performance Class

 

F

 

D

 

 

 

 

 

 

 

 

 

F

Hardfloor Cleaning Performance Class

 

D

 

A

 

 

 

 

 

 

 

 

 

G

Dust Re-Emission Class

 

E

 

E

 

 

 

 

 

 

 

 

 

H

Sound Power Level (dBA)

 

86

 

80

 

 

 

 

 

 

 

 

 

 

I

Rated Input Power (W)

 

 

1300

 

750

 

 

 

 

 

 

 

 

 

 

J

Type

 

 

General purpose vacuum cleaner

 

 

 

 

 

 

 

 

 

 

1)Indicative annual energy consumption (kWh per year), based on 50 cleaning tasks. Actual annual energy consumption will depend on how the appliance is used.

2)Measurements for power consumption and performance are based on methods in EN 60312-1 and EN 60704.

EN-10