Pump filter

It is advisable to clean the pump filter 5 or 6 times a year to prevent its clogging. A clogged pump filter may reduce the bubble effect.

1.

Turn off the washing machine, and

A

unplug the power cord.

Drain the remaining water inside

 

 

2.

 

 

 

 

the drum. See the “Emergency drain”

 

 

 

 

 

 

section.

3.

Gently press the top area of the filte

 

 

 

cover to open.

4.

Turn the pump filter knob (A) to the left,

 

 

 

and drain off the remaining water.

5.

Clean the pump filter using soft

 

 

 

brushes. Make sure the drain pump

 

 

 

propeller inside the filter is unclogged.

6.

Reinsert the pump filter, and turn the

 

 

 

filter knob to the right.

NOTE

• Some pump filters feature a safety knob that is designed to prevent accidents by children. To open the safety knob of the pump filter, push in and turn it anticlockwise. The spring mechanism of the safety knob helps open the filter.

• To close the safety knob of the pump filter, turn it clockwise. The spring makes a rattling sound, which is normal.

NOTE

If the pump filter is clogged, an information code of “5C” appears on the screen.

CAUTION

Make sure the filter knob is closed properly after cleaning the filter. Otherwise, this may cause a leak.

Make sure the filter is inserted properly after cleaning it. Otherwise, this may cause an operational failure or a leak.

Maintenance

English  47 

 

 

 

 

WD19J9810KG_DC68-03474G-01-EN.indd 47

2016/6/17 19:05:18