NOTE: Turn off the switch and unplug the electrical cord before servicing.

PROBLEM

SOLUTION

 

Motor will not start.

Push plug securely into outlet.

 

 

Try another outlet.

 

 

Check circuit breaker.

 

Motor suddenly

Thermal Cut Off, see Page 2.

 

stops.

 

 

Does not clean the

Clean or replace the filters: Hint: If picking

 

carpet or floor.

up fine dust, the filters may not look dirty, but a

 

 

fine substance tends to reduce suction when it

 

 

blocks the airflow through the filters.

 

 

Be sure the dust bag is properly seated into the

 

 

cleaner body. Page 8.

 

 

Replace dust bag. Page 8.

 

 

Be sure hose adapter is secure on back of cleaner.

 

 

Page 11.

 

 

Check base hose and long hose. Page 11.

 

 

Replace a broken, cut, loose or out of shape belt.

 

 

Clean hair and thread from bristles and end cap

 

 

area.

 

 

Replace brush roll if bristles are worn.

 

No suction at the

Be sure hose adapter is secure. Page 11.

 

end of hose.

Clean or replace filters. Hint: If picking up fine dust,

 

 

 

 

the filters may not look dirty, but a fine substance

 

 

tends to reduce suction when it blocks the airflow

 

 

through the filters.

 

 

Remove any clogs from the hose that restrict the

 

 

airflow. Check base hose and long hose. Page 11.

 

 

Replace dust bag. Page 8

 

Headlight not

Replace light bulb. Page 9.

 

working.

 

 

Noise from brush

Remove hood and clean debris or items

 

roll area.

from the brush roll area.

 

 

Replace a broken, cut, loose or out of shape belt.

 

 

Page 10.

 

Cleaner is hard to

Put handle in operating position. Tilt the

 

push.

cleaner back to raise the front wheels off floor.

 

 

Then turn the knob to a higher setting.

 

 

Replace a broken, cut loose or out of shape belt.

 

 

Page 10.

 

Cleaner height knob

Hint: Put handle in operating position. Tilt

 

will not turn.

the cleaner back to raise the front wheels off floor.

 

 

Then turn the knob.

 

Bag Cover will not go

Dust bag must be installed properly in cleaner or

 

onto cleaner properly.

bag cover will not go onto cleaner. Make sure the

 

 

dust bag cardboard flange is on the support shelf.

 

 

See page 6.

 

Hood will not come off.

Hood cannot be removed from cleaner unless the

 

 

cleaner height setting is in the lowest or highest

 

 

position.

 

 

All three screws must be removed from the top of

 

 

the hood. Page 10.

 

Missing parts or

Call 1-800-800-8975 between 8 a.m. to 7:30 p.m.

 

questions?

(CST), Monday through Friday and 10 a.m. to 6:30

 

 

p.m, Saturday. Know the model and serial num-

 

 

bers when you call.

 

 

 

©2003 White Consolidated, Ltd.

Part No. 73524 (10/03)

Printed in U.S.A.

Page 12
Image 12
Sanitaire SC5800 Series warranty Problem, Solution, Part No. 73524 10/03