Indoor Unit

KS0971

Control PCB

Part No.

Controls

Control Circuit Fuse

Remote Control Unit

Fan

CB-KS0971

Microprocessor

250V 3A

RCS-4VPIS4U

Type

 

Q'ty ... Dia. and Length

inch (mm)

Cross-Flow

1 ... D3-11/16 / L24-31/32 (D94/L634)

Fan Motor

 

 

 

 

Type

 

 

AC Motor

 

Model ... Q'ty

 

 

IBH-884-076 ... 1

 

No. of Poles

 

 

4

 

Rough Measure RPM (Cool)

 

 

1,200

 

Nominal Output

 

W

16

 

Coil Resistance

 

Ohm

BRN-WHT : 57.9

 

(Ambient Temp. 68 °F (20 °C))

 

 

RED-WHT : 55.2

 

Safety Device

 

 

 

 

 

Type

 

 

Thermal Fuse

 

 

Operating Temp.

Open °F (°C)

266 (130)

 

 

 

Close °F (°C)

-

 

Run Capacitor

 

Micro F

4.5

 

 

 

 

VAC

250

 

 

 

 

 

 

Flap Motor

 

 

 

 

Type

 

 

Stepping Motor

 

Model

 

 

MP24Z3

 

Rating

 

 

DC 12V

 

Coil Resistance

 

Ohm

Each Pair of Terminal : 400 +/- 7%

 

(Ambient Temp. 77 °F (25 °C))

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

Coil

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

2

 

Fins per inch

 

 

19.5

 

Face Area

 

ft2 (m2)

2.02 (0.188)