Sanyo C0971, CL0971 service manual CL1271, C1271 Cooling

Models: CL0971 C1271 C0971 CL1271

1 108
Download 108 pages 37.94 Kb
Page 31
Image 31

Indoor Unit

KS1271

 

 

 

 

Outdoor Unit

C1271

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

Performance at

 

 

 

 

115V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.45

10.45

10.9

 

 

 

Power input

W

45

1,045

1,090

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Indoor Unit

KS1271

 

 

 

 

Outdoor Unit

CL1271

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

Performance at

 

 

 

 

 

115V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.45

10.45

10.9

 

 

 

Power input

W

45

1,045

1,090

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 