Sanyo CL1271, C1271, CL0971 Electrical Data, Electrical Characteristics, C0971 Cooling

Models: CL0971 C1271 C0971 CL1271

1 108
Download 108 pages 37.94 Kb
Page 30
Image 30

6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit

KS0971

 

 

 

 

Outdoor Unit

C0971

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

Performance at

 

 

 

 

115V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.45

7.15

7.6

 

 

 

Power input

W

45

705

750

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Indoor Unit

KS0971

 

 

 

 

Outdoor Unit

CL0971

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

Performance at

 

 

 

 

 

115V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.45

7.15

7.6

 

 

 

Power input

W

45

705

750

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

30

Page 30
Image 30
Sanyo CL1271, C1271, CL0971 service manual Electrical Data, Electrical Characteristics, C0971 Cooling