Special Remarks

``DRY'' ( ) Operation

How it works?

Once the room temperature reaches the level that was set, the unit

 

repeats the cycle of turning on and off automatically.

 

During DRY operation, the fan speed is automatically set to LOW or

 

 

VERY LOW; the fan speed then switches back and forth between

 

 

LOW (for 20 seconds) and VERY LOW (for 10 seconds).

 

“DRY” operation is not possible if the indoor temperature is 59°F or

 

 

less.

Heating ( ) Operation

Heating performance

Defrosting

STANDBY lamp

STANDBY lamp

OPERATION STANDBY TIMER

Power failure during operation

Clicking Sound

Clicking sound is heard from the air conditioner

Remote Control Unit

Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it.

When the outdoor temperature is low, frost or ice may form on the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan on the indoor unit stops and the STANDBY lamp remains lit until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms).

For several minutes after the start of heating operation, the indoor fan will not start running until the indoor heat exchanger coil has warmed up sufficiently. This is because the COLD DRAFT PREVENTION SYSTEM is operating. During this period, the STANDBY lamp remains lit.

The STANDBY lamp also remains lit during defrosting or when the compressor has been turned off by the thermostat when the system is in the heating mode.

Upon completion of defrosting and when the compressor is turned on again, for heating operation, the STANDBY lamp will go off automatically.

In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically after five minutes.

In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.

The remote control unit sends the setting condition to the air conditioner regularly at five minute intervals.

18

OI-351-18EG

Page 18
Image 18
Sanyo KHS1852, KHS0951 Special Remarks, ``DRY Operation, Heating Operation, Power failure during operation Clicking Sound

KHS1251, KHS0951, KHS1852 specifications

Sanyo is renowned for manufacturing high-quality, energy-efficient refrigeration solutions, and their KHS series showcases the brand's commitment to innovation and performance. Among these models, the KHS1852, KHS0951, and KHS1251 stand out due to their advanced technologies and unique features.

The Sanyo KHS1852 is a commercial refrigerator that offers impressive storage capacity with a focus on maintaining optimal temperatures. Its large interior can accommodate various food items, making it perfect for restaurants or grocery stores. This model is equipped with a digital control system that ensures precise temperature regulation, ranging from 0°C to 10°C, which is crucial for preserving the freshness of perishable goods. The KHS1852 utilizes high-density insulation to minimize temperature fluctuations and reduce energy consumption, enhancing its overall efficiency.

Next in the series is the KHS0951, which is more compact while still providing excellent cooling performance. This model is designed for smaller spaces without sacrificing functionality. The KHS0951 features a stainless-steel exterior, making it not only durable but also easy to clean. Its user-friendly digital display allows for quick adjustments to the temperature settings, ensuring that food safety standards are consistently met. The efficient cooling system operates quietly, making it ideal for use in cafes or small kitchens where noise levels need to be kept to a minimum.

The KHS1251 strikes a balance between size and performance, incorporating features from both the KHS1852 and KHS0951. It boasts a spacious interior that can store a variety of refrigerated products. The unit is designed with advanced cooling technologies, including a forced air circulation system that ensures even temperature distribution throughout the cabinet. This feature minimizes hotspots and guarantees that all stored items are kept at the desired temperature. Additionally, the KHS1251 comes with adjustable shelves, allowing for customizable storage configurations to accommodate different food items.

All three models are designed with energy efficiency in mind, featuring eco-friendly refrigerants that adhere to modern environmental standards. Sanyo's commitment to sustainability is evident in its focus on energy-saving technologies that help reduce operational costs for businesses.

In conclusion, the Sanyo KHS1852, KHS0951, and KHS1251 are exceptional refrigeration solutions suitable for a variety of commercial applications. With their unique features, advanced technologies, and high energy efficiency, these models are designed to meet the needs of food service operations while ensuring the preservation of food quality and safety.