Sanyo MPX-MD4 RS232C CONTROL, INFORMATION GATHERING COMMANDS STATUS SENSED7, ALARM STATUS SENSED5

Models: MPX-MD4

1 41
Download 41 pages 4.14 Kb
Page 37
Image 37
RS232C CONTROL

RS232C CONTROL

INFORMATION GATHERING COMMANDS

STATUS SENSE(D7)

When this command is sent from the computer, this unit will send a 5-byte response (see Table 1).

RXD

D7

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

d1

 

d2

 

d3

 

d4

 

d5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS SENSE(D7) byte assignment (Table 1)

Fourth and fifth bytes are reserved.

First byte

Bit

 

Bit state information

7

LIVE/VCR indication

0: LIVE picture mode

 

 

1: VCR playback mode

6

Monitor 1 display

000:

Full screen

5

mode indication

001:

4 divisions split screen

 

4

 

010:

Menu display

3

Monitor 1 displayed

(Full screen mode)

2

channel depending

0000: Channel 1

on the display mode

1

0001: Channel 2

indication

0

0010: Channel 3

 

 

 

0011: Channel 4

 

 

(4 divisions split screen)

Third byte

Bit

 

Bit state information

7

Reserved

6

Reserved

5

Monitor 2 operation

MON2 setup

4

Monitor 2 operation

0: Full screen

 

 

1: Sequential display

3

Monitor 2 displayed

0000: Channel 1

2

channel

0001: Channel 2

 

1

 

0010: Channel 3

0

 

0011: Channel 4

ALARM STATUS SENSE(D5)

The external and video loss alarm states are indicated by a 6-byte response (see Table 2).

RXD

D5

 

 

 

 

 

 

 

 

 

 

 

 

 

TXD

 

 

d1

 

d2

 

d3

 

d4

 

d5

 

d6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM STATUS SENSE(D5) byte assignment (Table 2)

0000: 4 divisions split screen (channels

1, 2, 3, 4)

(Menu display)

0000: (LANGUAGE/LANG./IDIO.) menu

0001: (CLOCK SET) menu

0010: (TITLE SET) menu

0011: (ALARM SET) menu

0100: (SENSOR SET) menu

0101: (TIMER SET) menu

0110: (DISPLAY SET) menu

0111: (VCR SET) menu

First byte

Bit

70

60

50

40

3ALARM ON 4

2ALARM ON 3

1ALARM ON 2

0ALARM ON 1

Second byte

Bit

70

60

50

40

30

20

10

00

1000: (ALARM DATA) menu

Second byte

Bit

 

Bit state information

7

EXT/ALARM

EXT and ALARM are ON

 

indication

 

6

VIDEO LOSS

VIDEO LOSS is ON

 

indication

 

5

SENSOR indication

SENSOR is ON

4

Reserved

0

3

Monitor 1 display

0000: Normal display mode

 

state mode indication

 

Third byte

Bit

70

60

50

40

3SENSOR 4

2SENSOR 3

1SENSOR 2

0SENSOR 1

Fourth byte

Bit

70

60

50

40

30

20

10

00

2

0001: Sequential display mode

1

0010: Zoomed in mode

0

0011: Still image mode

 

0100: Frozen zoomed in image

 

0101: Zoomed in still image

 

0110: Zoom range setting mode

 

0111: Zoomed in still image range setting

 

mode

Fifth byte

Bit

70

60

50

40

3VIDEO LOSS 4

2VIDEO LOSS 3

1VIDEO LOSS 2

0VIDEO LOSS 1

Sixth byte

Bit

70

60

50

40

30

20

10

00

36

English

Page 37
Image 37
Sanyo MPX-MD4 RS232C CONTROL, INFORMATION GATHERING COMMANDS STATUS SENSED7, STATUS SENSED7 byte assignment Table