Sanyo MPX-MD4 COMMANDS AVAILABLE FROM THE MULTIPLEXER ACK0A, NAK0B, Alarmbf, CLEAR56

Models: MPX-MD4

1 41
Download 41 pages 4.14 Kb
Page 38
Image 38
 COMMANDS AVAILABLE FROM THE MULTIPLEXER

RS232C CONTROL

NAK(0B) COMMANDS AVAILABLE FROM THE MULTIPLEXER

ACK(0A)

Response when this unit receives a command.

NAK(0B)

Response if this unit did not receive the command.

ALARM(BF)

When there is an alarm, this command is sent as header. Then, the alarm information is sent in a 1-byte transmission (see Table 3).

ALARM information (Table 3)

Bit

 

Bit state information

7

Alarm information

01: External

6

indication

10: Video loss

 

 

11: Sensor alarm

5

Reserved

0

4

Reserved

0

3

Camera number

0011: CAMERA NO. 4

2

indication

0010: CAMERA NO. 3

 

1

 

0001: CAMERA NO. 2

0

 

0000: CAMERA NO. 1

ALARM(BF) OTHER COMMANDS

ENTER(40)

When numeric commands are all sent, this command is used to enter the transmitted value.

CLEAR(56)

To erase multiple byte commands.

English

37

Page 38
Image 38
Sanyo MPX-MD4 COMMANDS AVAILABLE FROM THE MULTIPLEXER ACK0A, NAK0B, Alarmbf, ALARM information Table, CLEAR56