1.Voltage adjustment is necessary to repair in the PW1 board and replace the parts.
2.Power voltage set about +3.0 V.
Preparation:1.Connect CN104 on the CA2 board and CN502 on the PW1 board with extension cord.
2.Open the barrier switch.
3.Slide the slide switch to camera, and turn on the LCD.
1. IC501 Oscillation Frequency AdjustmentMeasuring Point | |
|
|
Measuring Equipment | Frequency counter |
|
|
ADJ. Location | VR501 |
|
|
ADJ. Value | 200 ± 1 kHz |
1.Adjust with VR501 to 200 ± 1 kHz.
2.5.0 V (D) Voltage AdjustmentMeasuring Point | CL539 |
|
|
Measuring Equipment | Digital voltmeter |
|
|
ADJ. Location | VR505 |
|
|
ADJ. Value | 5.10 ± 0.05 V |
Adjustment method:
1. Adjust with VR505 to 5.10 ± 0.05 V.
3. 3.3 V (D) A Voltage AdjustmentMeasuring Point | R5056 below |
|
|
Measuring Equipment | Digital voltmeter |
|
|
ADJ. Location | VR503 |
|
|
ADJ. Value | 3.30 ± 0.02 V |
Measuring Point | L5009 ST side |
|
|
Measuring Equipment | Digital voltmeter |
|
|
ADJ. Location | VR504 |
|
|
ADJ. Value | 3.40 ± 0.03 V |
Adjustment method:
1. Adjust with VR504 to 3.40 ± 0.03 V.
5. 12.4 V (L) Voltage Adjustment 1Measuring Point | |
|
|
Measuring Equipment | Digital voltmeter |
|
|
ADJ. Location | VR507 |
ADJ. Value | 12.40 ± 0.05 V |
|
|
Adjustment method:
1.Set the play mode.
2.Adjust with VR507 to 12.40 ± 0.05 V.
6. 12.4 V (L) Voltage Adjustment 2Measuring Point | |
|
|
Measuring Equipment | Digital voltmeter |
|
|
ADJ. Location | VR506 |
|
|
ADJ. Value | 12.40 ± 0.05 V |
Adjustment method:
1.Set the view mode, and turn on the LCD.
2.Adjust with VR506 to 12.40 ± 0.05 V.
7. AWB AdjustmentSerial cable
Camera 0 - 18 cm
All white pattern
Color viewer (5,100K)
Preparation:
POWER switch: ON
Adjusting method:Adjustment method:
1.Adjust with VR503 to 3.30 ± 0.02 V
1.When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.)
2.
3.Click the AWB, and click the Yes.