4.AWB adjustment value will appear on the screen.
5.Click the OK.
8. Lens AdjustmentSerial cable
CameraApprox.
95 cm ± 3 cm
Siemens star chart
Preparation:
POWER switch: ON
Adjustment condition:More than A3 size siemens star chart Fluorescent light illumination with no flicker Illumination above the subject should be 400 lux ± 10 %.
Adjustment method:
1.Set the siemens star chart 95 cm ± 3 cm so that it be- comes center of the screen.
2.
3.Click the Focus, and click the Yes.
4.Lens adjustment value will appear on the screen.
5.Click the OK.
9.CCD Defect Detect AdjustmentPreparation:
POWER switch: ON (Set the camera mode.)
Adjustment method:
1.
2.Select CCD Defect Detection on the LCD “Test”, and click the “Yes”.
3.After the adjustment is completed, OK will display.
4.Click the OK.
VR171
CL170
CL173
CL171 CL172
Preparation:
POWER switch: ON
Adjusting method:
1.
2.Select 0 on the LCD “H AFC”.
3.Apply the trigger at CL173, and adjust VR171 so that the time A from the point where the pulse at CL170 rises until the position where the video signal at CL173 starts in 0.82
±0.1 ∝ sec (for
±0.1 ∝ sec (for
A
CL170
CL173
enlargement
A
CL170
CL173