4.AWB adjustment value will appear on the screen.

5.Click the OK.

8. Lens Adjustment

Serial cable

CameraApprox.

95 cm ± 3 cm

Siemens star chart

Preparation:

POWER switch: ON

Adjustment condition:

More than A3 size siemens star chart Fluorescent light illumination with no flicker Illumination above the subject should be 400 lux ± 10 %.

Adjustment method:

1.Set the siemens star chart 95 cm ± 3 cm so that it be- comes center of the screen.

2.Double-click on the DscCalDi126.

3.Click the Focus, and click the Yes.

4.Lens adjustment value will appear on the screen.

5.Click the OK.

9.CCD Defect Detect Adjustment

Preparation:

POWER switch: ON (Set the camera mode.)

Adjustment method:

1.Double-click on the DscCalDi126.

2.Select CCD Defect Detection on the LCD “Test”, and click the “Yes”.

3.After the adjustment is completed, OK will display.

4.Click the OK.

10. LCD Panel Adjustment[CA3 board (Side A)]

VR171

CL170

CL173

CL171 CL172

10-1. LCD H AFC Adjustment

Preparation:

POWER switch: ON

Adjusting method:

1.Double-click on the DscCalDi126.

2.Select 0 on the LCD “H AFC”.

3.Apply the trigger at CL173, and adjust VR171 so that the time A from the point where the pulse at CL170 rises until the position where the video signal at CL173 starts in 0.82

±0.1 sec (for VPC-SX560EX and VPC-SX560E) or 1.5

±0.1 sec (for VPC-SX560).

A

CL170

CL173

enlargement

A

CL170

CL173

– 19 –