1-5. PW1 STROBE CIRCUIT DESCRIPTION
1. Charging CircuitWhen UNREG power is supplied to the charge circuit and the CHG signal becomes High (3.3 V), the charging circuit starts operating and the main electorolytic capacitor is charged with
However, when the CHG signal is Low (0 V), the charging circuit does not operate.
When the CHG signal switches to Hi, Q5406 turns ON and the charging circuit starts operating.
L5401 and C5401 constitute the power supply filter. They smooth out ripples in the current which accompany the switching of the oscillation transformer.
This circuit generates an AC voltage (pulse) in order to increase the UNREG power supply voltage when drops in current occur. This circuit generates a drive pulse with a frequency of approximately
The
The
This circuit is used to maintain the voltage accumulated at C5412 at a constance level.
After the charging voltage is divided and converted to a lower voltage by R5417 and R5419, it is output to the SY1 circuit board as the monitoring voltage VMONIT. When this VMONIT voltage reaches a specified level at the SY1 circuit board, the CHG signal is switched to Low and charging is interrupted.
When RDY and TRIG signals are input from the ASIC expansion port, the stroboscope emits light.
When the RDY signal is input to the emission control circuit, Q5409 switches on and preparation is made to let current flow to the light emitting element. Moreover, when a STOP signal is input, the stroboscope stops emitting light.
When a TRIG signal is input to the trigger circuit, D5405 switches on, a
When the