Parallel Input Cable (Centronics 36 pin)

CX400 User Guide

Parallel Input Cable (Centronics 36 pin)

 

 

 

 

 

 

 

 

 

Pin #

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

STROBE

 

 

 

 

 

 

 

2~9

 

Data bits 0-7

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

ACK

 

 

 

 

 

 

 

11

 

Busy

 

 

 

 

 

 

 

12

 

PE (Paper End)

 

 

 

 

 

 

 

13

 

Select, always high

 

 

 

 

 

 

 

16

 

Signal Ground

 

 

 

 

 

 

 

17

 

Chassis Ground

 

 

 

 

 

 

 

18

 

+5V DC

 

 

 

 

 

 

 

19~30

 

Ground

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Port Parameters

CX400 printers are configured as Data Terminal Equipment (DTE) equipment, and use Request-To-Send/Clear-To-Send (RTS/CTS) handshaking or X-On/X-Off flow control (control characters are DC2 and DC4). The serial port supports the following parameters:

Speed

9600,19200 or 38400 bps

Parity

Odd, Even or None

Data Bits

7 or 8 bits

Stop Bit(s)

1 or 2

Default Parameters

9600 bps, No parity, 8 data bits, 1

 

stop bit