SATO MB200 manual Battery isn’t full

Models: MB200

1 49
Download 49 pages 25.36 Kb
Page 39
Image 39
Battery isn’t full

The power will automatically be turned off 30 seconds before low battery is indicated. Make sure the power is off before removing the battery pack, and recharge the battery.

 

 

 

 

Cause

Solution

 

 

 

 

Battery isn’t full

Recharge the batteries

 

 

 

 

 

 

 

1.Received data over the buffer

1.Adjust the data amount at the

 

 

 

 

quota.

host side so that it won’t

 

 

 

 

 

exceed the buffering quota.

 

 

 

 

 

 

 

 

 

2.The protocol between the

2.Match the protocol

 

 

 

 

printer and host doesn't match

 

 

 

 

 

FLASH ROM reading/writing

1.Replace the FLASH ROM *

 

 

 

 

error

2.Download the program again *

 

 

 

 

The head is broken

Replace the head *

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Cover isn't locked

1.Lock the cover

 

 

 

 

2.Cover micro switch is not

2.Adjust the micro switch *

 

 

 

 

working properly

 

 

 

 

 

Out of paper

Set new label

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Sensor level isn't accurate.

1.Adjust the sensor level *

 

 

 

 

2.Sensor type doesn't match.

2.Adjust the sensor type

 

 

 

 

3.Label is meandering

3.Reset the labels properly

 

 

 

 

You are approaching the quota

Pause the data transmission and

 

 

 

 

on the buffer

wait till the buffer is empty before

 

 

 

 

 

trying again

 

 

 

 

Not an error. The over heating

The function will deactivate when

 

 

 

 

protection function activates

the head temperature goes down

 

 

 

 

when the head temperature rises

to 50°C.

 

 

 

 

 

 

 

above 55°C.

 

* Consult your local dealer or Customer Service Center.