SATO XL4xxe manual Chart, previous home next, Electric Checks and Adjustments

Models: XL4xxe

1 13
Download 13 pages 26.78 Kb
Page 4
Image 4
Chart 2

EZ Manual: XL4xxe

4

 

 

 

 

Electric Checks and Adjustments

 

 

 

 

Chart 2

 

TP TEST POINT CHART

 

 

 

 

 

 

 

 

 

 

Dial test point

Comment

Voltage

Voltage Range

Check pin on TP Test Module and Main PCB

Adjustment to VR

 

 

 

 

 

 

0

 

+5.0 VDC

+4.8V to +5.2V

CH3A(+5.0V) - CH1A(GND)

N/A

 

 

 

 

 

 

1

 

+2.0 VDC

+1.9V to +2.1V

CH4A(+2.0V) - CH1A(GND)

N/A

 

DC power Supply

 

 

 

 

2

+3.3 VDC

+3.1V to +3.5V

CH5A(+3.3V) - CH1A(GND)

N/A

 

 

 

 

 

 

 

3

 

+24.0 VDC

+23.5V to +24.5V

CH6A(+24.0V) - CH1A(GND)

N/A

 

 

 

 

 

 

 

 

Low level (Set the no eye-mark point

 

VR8 and VR2

 

 

in the sensor’s) = Less than +0.5V

 

 

 

 

 

 

 

 

 

 

4

I-Mark Sensor Level

High level (Set the eye-mark in the sensor’s)

CH1B(+8.4V) - CH1A(GND)

(VR2 is used for adjusting the

= Low level plus more than +0.9V

light reception flow. If there is

 

 

 

 

 

difference between the high and

 

 

 

 

 

 

 

High level (with eye-mark point) - Low level

 

low level, adjust VR2 to allow

 

 

(without eye-mark point) = +0.9V

 

some level difference.)

 

 

 

 

 

 

 

 

Low level (Set the label backing liner or centre

 

 

 

 

hole tag in the sensor’s) = Less than +0.5V

 

 

 

 

 

 

 

5

Gap/Tag Center

High level (Set the label and tag in the

CH2B - CH1A(GND)

VR1 and VR9 (Fine adjustment)

sensor’s) = Low level plus more than +0.1V

 

Hole Sensor Level

 

 

 

 

 

 

 

 

 

High level (printing point) -

 

 

 

 

Low level (gap point) = +1.0V

 

 

 

 

 

 

 

 