Cutter Sensor Adjustment continued

Cut sensor type

Sensor Level Voltage

 

 

 

 

High level (Position a TAG in the

: More than (+) 6.0Volts to less than

 

sensor’s field of view.)

(+) 7.0Volts

Center Hole

 

 

Low level (Position a Center Hole

: Less than (+) 0.5Volts

 

 

in the sensor’s field of view.)

 

 

 

 

 

High level (Position a I-Mark in the

: More than (+) 6.0Volts to less than

 

sensor’s field of view.)

(+) 7.0 volts

I-Mark

 

 

Low level (Position a NON I-Mark

: Less than (+) 0.5Volts

 

 

in the sensor’s field of view.)

 

 

 

 

 

High level (Position a TAG in the

: More than (+) 6.0Volts to less than

 

sensor’s field of view.)

(+) 7.0Volts

R-Corner

 

 

Low level (Position a R-Corner in the

: Less than (+) 0.5Volts

 

 

sensor’s field of view.)

 

 

 

 