TP TEST POINT CHART

 

 

 

 

 

 

 

 

 

 

 

 

Dial test point

Comment

Voltage

 

Voltage Range

Check pin on TP Test Module and Main PCB

Adjustment to VR

 

 

 

 

 

 

 

 

Low level (Set the ribbon without

 

 

 

 

slit point) : Less than +0.5V

 

 

6

Ribbon sensor

 

 

 

CH3B - CH1A(GND)

VR3

 

 

 

 

level adjustment

High level (with slit point) - Low level

 

 

 

 

(without slit point) +2.0V

 

 

 

 

 

 

 

 

 

 

Low level (Set the side hole in

 

 

 

 

the sensor’s) : Less than +0.5V

 

 

 

 

 

 

 

 

 

High level (Set the tag in the

 

 

7

Side hole

sensor’s) : Low level plus more than +0.2V

CH4B - CH1A(GND)

VR5

 

sensor level

 

 

 

 

 

 

High level (printing point) - Low level

 

 

 

 

 

 

 

 

(side hole point) : +2.0V

 

 

 

 

 

 

 

 

N/A

Side hole slice level

Middle of level between high

TP1 - TP4(GND)

VR12

 

 

 

and low levels

 

 

 

 

 

 

 

 

 

 

 

 