Scag Power Equipment STT61V-25KBD manual Battery, Engine Air Cleaner

Models: STT61V-25KBD

1 79
Download 79 pages 33.87 Kb
Page 39
Image 39

Section 7

R

B. Replacing In-Line Fuel Filter Elements

- NOTE -

The fuel filter is located below the air filter. Figure 7-5 is for illustration purposes only.

The in-line pre-filter (Kubota engine only) and the engine fuel filter (Figure 7-5) should be replaced after every 500 hours of operation or annually, whichever occurs first.

1.Close the shut-off valve.

2.Remove and replace the engine fuel filter. Open the fuel shut-off valve.

7.7 Battery

WARNING

Lead-acid batteries produce flammable and explosive gases. To avoid personal injury when checking, testing or charging batteries, DO NOT use smoking materials near batteries. Keep arcs, sparks and flames away from batteries. Provide proper ventilation and wear safety glasses.

7.6 Engine Air Cleaner

A. Cleaning and/or Replacing Air Cleaner Element

For any air cleaner, the operating environment dictates the air cleaner service periods. To make it convenient for you we have installed an "Air Cleaner Indicator" which is located just behind the air filter. The indicator window will turn red when it is time to service the air filter. Do not service the filter unless this indicator is red.

- NOTE -

In extremely dusty conditions it may be necessary to check the indicator daily to prevent engine damage.

1.Snap open the two clips securing the air cleaner cover to the air cleaner box. Remove the air cleaner cover, clean the duck bill vent of any dust and set the cover aside.

2.Remove the air cleaner element and inspect.

3.Clean or replace the element as recommended by the engine manufacturer.

4.Replace the air filter cover and be sure to snap the two clips closed.

5.Reset the air cleaner indicator by pushing the button on the end of the indicator. The indicator window should return to clear.

WARNING

Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to cause cancer and reproductive harm. Wash hands after handling.

WARNING

Electric storage battery fluid contains sulfuric acid which is POISON and can cause SEVERE CHEMICAL BURNS. Avoid contact of fluid with eyes, skin, or clothing. Use proper protective gear when handling batteries. DO NOT tip any battery beyond 45° angle in any direction. If fluid contact does occur, follow first aid suggestions below.

BATTERY ELECTROLYTE FIRST AID

External Contact — Flush with water.

Eyes — Flush with water for at least 15 minutes and get medical attention immediately.

Internal — Drink large quantities of water. Follow with Milk Of Magnesia, beaten egg, or vegetable oil. Get medical attention immediately. In case of internal contact, DO NOT give fluids that would induce vomiting.

35

Page 39
Image 39
Scag Power Equipment STT61V-25KBD manual Battery, Engine Air Cleaner, Replacing In-Line Fuel Filter Elements