930-112-01-B.00

PowerLogicTM EM4800 Series

01/2011

PowerLogic configuration tool

 

 

 

 

Table 2: Unit Field Configuration tab parameters

 

 

 

 

Field

Parameter

 

Description

 

 

 

 

Unit Field Configuration

Current IP Address

 

The current IP address for the unit .This parameter is read only and cannot

 

 

 

be changed by the user.

 

 

 

 

 

Mac Address

 

The current MAC address for the unit. This parameter is read only and

 

 

 

cannot be changed by the user.

 

 

 

 

 

Revision

 

The revision number of the unit.

 

 

 

 

Default IP Configuration

IP Address

 

The default IP address. This parameter is configured when DHCP has

 

 

 

been disabled, or DHCP services are not available on the network.

 

 

 

 

 

Netmask

 

The default subnet mask. This parameter is configured when DHCP has

 

 

 

been disabled, or DHCP services are not available on the network.

 

 

 

 

 

Gateway

 

The default gateway. This parameter is configured when DHCP has been

 

 

 

disabled, or DHCP services are not available on the network.

 

 

 

 

 

DNS Primary

 

The primary domain name server. This parameter is configured when

 

 

 

DHCP has been disabled, or DHCP services are not available on the

 

 

 

network.

 

 

 

 

 

DNS Secondary

 

The secondary domain ame server. This parameter is configured when

 

 

 

DHCP has been disabled, or DHCP services are not available on the

 

 

 

network.

 

 

 

 

 

DHCP Enabled

 

If DHCP is not enabled, the meter uses the Default IP Configuration

 

 

 

parameters. If DHCP is enabled, the meter uses the IP configuration

 

 

 

parameters provided by the network DHCP service.

 

 

 

Report

See “Report Parameters” on

 

 

page 12

 

 

 

 

 

 

Main Meter

PT Ratio

 

The main meter potential transformer ratio. This is an internal multiplier

 

 

 

used by the meter for external potential transformers. External PTs can be

 

 

 

used with a PT ratio of 1 if the billing system will apply the PT muliplier.

 

 

 

Use a PT Ratio of 1 with no external PTs.

 

 

 

 

Modem

Phone #

 

The phone number of your internet service provider’s PPP service.

 

 

 

 

 

Alternate Phone #

 

An alternate phone number of your internet service provider’s PPP service.

 

 

 

 

 

AT String

 

AT command string to customize modem operation. Default string is ATX3,

 

 

 

do not wait for dial tone.

 

 

 

 

 

Wait for Dial Tone

 

Do not enable this parameter if the line has a broken dial tone due to a

 

 

 

message waiting feature.

 

 

 

 

Host Server

IP Address

 

The IP address or domain name of the FTP server for data storage.

 

 

 

 

 

Upload Directory

 

The sub-directory used for data reporting within the root directory. The root

 

 

 

directory is determined by the FTP user name and the FTP server

 

 

 

configuration. The FTP account must have write access to this directory.

 

 

 

 

 

Download Directory

 

The sub-directory used by the meter to retrieve configuration updates. The

 

 

 

FTP account must have read access to this directory..

 

 

 

 

FTP Login

User Name

 

The user name for the FTP account.

 

 

 

 

 

Password

 

The password for the FTP account.

 

 

 

 

PPP Login

User Name

 

The user name for the PPP account. This is only required if using dial-up

 

 

 

reporting.

 

 

 

 

 

Password

 

The password for the PPP account. This is only required if using dial-up

 

 

 

reporting.

 

 

 

 

NTP Host (Time Server)

IP Address

 

The IP address of the NTP server that provides timing to the meter.

 

 

 

 

© 2011 Schneider Electric All Rights Reserved

11

Page 17
Image 17
Schneider Electric EM4800 manual Unit Field Configuration tab parameters, Field Parameter Description

EM4800 specifications

Schneider Electric, a global leader in energy management and automation, offers advanced power monitoring solutions that enhance energy efficiency and operational effectiveness. The EM4800 and EM400 series are prominent products in Schneider Electric’s energy monitoring line, designed specifically for efficient energy consumption management in various industrial and commercial applications.

The EM4800 is a comprehensive energy meter that caters to larger facilities and energy-intensive operations. One of its main features is its ability to monitor multiple electrical parameters, including voltage, current, frequency, power factor, and total active/reactive energy. The device supports diverse communication protocols such as Modbus, Ethernet, and BACnet, allowing seamless integration into existing building management systems. This diversity in communication enhances visibility into energy usage and supports real-time monitoring, enabling facility managers to make informed decisions.

On the other hand, the EM400 series is designed for smaller applications while still delivering robust functionality. This series is tailored for monitoring power consumption in smaller commercial buildings or branch offices. EM400 meters focus on essential energy metrics but do so with a compact, easy-to-install design. With features like demand forecasting and peak load management, the EM400 provides valuable insights that help organizations optimize their energy usage.

Both models come equipped with advanced technologies such as harmonic analysis, which is crucial for understanding power quality and mitigating potential risks associated with harmonic distortion. The user-friendly interface of these devices facilitates quick access to energy data, making it simple for users to analyze consumption patterns and identify opportunities for energy savings.

In concurrence with Schneider Electric’s commitment to sustainability, both the EM4800 and EM400 series emphasize energy conservation by promoting efficient energy practices. Users can leverage the collected data to reduce energy costs, enhance equipment performance, and contribute to environmental sustainability efforts.

In summary, Schneider Electric’s EM4800 and EM400 energy meters combine innovative technology with practical features aimed at improving energy management. Their advanced monitoring capabilities, versatile communication options, and focus on power quality make them essential tools for organizations seeking to enhance operational efficiency while reducing their carbon footprint. By investing in these cutting-edge energy solutions, businesses can take significant strides towards sustainable energy management and operational excellence.