SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL

KERR SCOTSMAN Wood Furnace

Model DB-101-ADD

Tested and Listed by:

Energy Testing Laboratory of Maine

Certified by the Canadian Standards Association

(CSA) Sept. 1981

COSP No. WCP 001

Free-Standing

 

COSP No. WCP 005

Add-On

 

Manufactured by: Parrsboro Metal Fabricators Ltd. P.O. Box 637, Crossroads 12118 Highway 209 Parrsboro Nova Scotia, Canada B0M 1S0

SPECIFICATIONS

Length

 

39”

Width

 

29”

Height

 

44 1/2”

Shipping Weight

 

392 lb.

Fire Box 1/8”plate

Length

36”

 

Diameter

23”

Secondary Heat Exchanger

14 gauge steel

Fire Box Door

Cast Iron

13” x 13”

Warm Air Plenum

 

32 1/4” x 25 1/2”

Return Air Plenum

 

N/A

Air Filter Size

 

20” x 20”

Blower Size

 

G9 – 10

Blower Motor

 

1/4 hp

C.F.M.

 

1000 (Required)

Smoke Pipe

 

7” Inside Diameter

Floor to smoke pipe center

38 3/4”

Output (max)

 

140,000 Btu/h

Fuel

 

Wood 30” logs

Electrical Rating

 

Volts 120, Cycles 60, Amps 15

NOTE – Keep this manual in a safe place for future reference. Follow manual carefully for the correct way to install and operate this unit.

CAUTION – Do not fire this unit until operating instructions have been read and fully understood.

INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM

AND CHIMNEY THAT ARE IN GOOD CONDITION.

SAVE THESE INSTRUCTIONS