| SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL | |
KERR SCOTSMAN Wood Furnace | Model | |
Tested and Listed by: | Energy Testing Laboratory of Maine | |
Certified by the Canadian Standards Association | (CSA) Sept. 1981 | |
COSP No. WCP 001 | – |
|
COSP No. WCP 005 | – |
|
Manufactured by: Parrsboro Metal Fabricators Ltd. P.O. Box 637, Crossroads 12118 Highway 209 Parrsboro Nova Scotia, Canada B0M 1S0
SPECIFICATIONS
Length |
| 39” |
Width |
| 29” |
Height |
| 44 1/2” |
Shipping Weight |
| 392 lb. |
Fire Box 1/8”plate | Length | 36” |
| Diameter | 23” |
Secondary Heat Exchanger | 14 gauge steel | |
Fire Box Door | Cast Iron | 13” x 13” |
Warm Air Plenum |
| 32 1/4” x 25 1/2” |
Return Air Plenum |
| N/A |
Air Filter Size |
| 20” x 20” |
Blower Size |
| G9 – 10 |
Blower Motor |
| 1/4 hp |
C.F.M. |
| 1000 (Required) |
Smoke Pipe |
| 7” Inside Diameter |
Floor to smoke pipe center | 38 3/4” | |
Output (max) |
| 140,000 Btu/h |
Fuel |
| Wood 30” logs |
Electrical Rating |
| Volts 120, Cycles 60, Amps 15 |
NOTE – Keep this manual in a safe place for future reference. Follow manual carefully for the correct way to install and operate this unit.
CAUTION – Do not fire this unit until operating instructions have been read and fully understood.
INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM
AND CHIMNEY THAT ARE IN GOOD CONDITION.
SAVE THESE INSTRUCTIONS
Scotsman | 2 |