SEMS PDR BASE STATION
Battery replacement for the SEMS PDR Base Station is as follows:
1.Place the Base Station in a clean,
2.Set the Base Station with the control panel face up and the bot- tom of the unit accessible.
3.Remove the three (3) battery caps from the battery compartments
BATTERY ORIENTATION
AS SHOWN
BATTERY
CAPS (3)
FIGURE 12
BATTERY COMPARTMENTS ON BASE STATION
by unthreading them counterclockwise. See FIGURE 12.
4.Remove the six (6) depleted batteries.
5.Install six (6) fresh new “C” cell batteries, two in each battery compartment. Use six (6) of the following: Duracell MN1400, or Eveready Alkaline No. E93 or EN93. Insert batteries with the bot- tom
6.Replace the three (3) battery caps by threading them on clock- wise until snug.
7.Power up the Base Station and perform the REGULAR OPERA- TIONAL INSPECTION as defined in this instruction.
MAINTENANCE
Except for programming and battery changing, there are no service operations or user serviceable parts available to the user.
CHECK YOUR WORK!
BEFORE ASSEMBLY OF BATTERY COVER, CHECK TO SEE BATTERY IS A FRESH, NEW BATTERY OF THE TYPE INDICATED AND THAT EMS HAS BEEN INSTALLED PROPERLY.
25