By causing
INSTALLATION ~ WORK HABITS
Installer's care should be stressed. No matter how good SEA FROST equipment is, it's performance and life are in the hands of the installer. To insure your work:
1.Read this manual.
2.Reread any aspect you don't understand.
3.Follow Swagelok fitting instructions carefully.
4.Install the RFD last and the same day the system is charged.
5.Spend enough time leak checking to be sure there are no leaks.
6.Thanks from all of us who have to guarantee your work.
There are two contaminants that will give you problems in a refrigeration system. They are WATER and DIRT. Moisture in the air is always present and cannot be eliminated; water in this case refers to puddles and drops. Dirt is any solid. The installer's habits will be most important in ensuring a
Excess moisture that the RFD can't handle will plug the expansion valve with ice. This ice stops the cycle. The only cure is to discharge the refrigerant, replace the RFD, evacuate the system, and recharge it. This remedy takes time and is somewhat costly. Keep the system clean and dry!
TUBE HANDLING
Installation is quite simple. All the copper tube comes to you with the ends capped. Any routing of the tubing must be done with the tube either taped or capped. Cap both tube ends after each cut. Work with only one line at a time, and uncap only one end at a time.