Appendix A The External Optical Bypass Module
The External Optical Bypass Module Front Panel
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-04 A-3
The External Optical Bypass Module Front Panel
The front panel of the External Optical bypass module contains the following components:
SUB Rx/Tx — GBE port that connects to the network element on the Subscriber side of the
link.
NET Rx/Tx — GBE port that connects to the network element on the Network side of the
link.
CONTROL — RJ-45 port that connects to the Bypass connector on the rear panel of the
SCE 2000 platform. The SCE 2000 platform controls the External Optical Bypass module
via this connection, by the presence or absence of electrical power.
Pigtail fiber connectors — Four fiber cables that connect to the GBE link ports on the front
panel of the SCE 2000 platform
NET Tx
NET Rx
SUB Tx
SUB Rx
No Bypass LED:
ON = Bypass module is not active (GBE traffic flows through the SCE 2000 platform)
OFF = Bypass module is active (GBE traffic flows through the bypass module)
Figure A-3: External Optical Bypass Module
Installing the External Bypass Module
Installation of the External Optical Bypass module requires two main steps, which are described
in detail in the following sections.
To install the External Optical Bypass module:
Step 1 Install the module in the rack.
Step 2 Cable the module.