Chapter 7 Basic SCE 2000 Platform Operations
Starting the SCE 2000 Platform
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-04 7-3
Final Tests
The procedures for performing the final tests to verify that the SCE 2000 is functioning properly
are explained in the following sections:
Verifying Operational Status (on page 7-3)
Viewing the User Log Counters (on page 7-3)

Verifying Operational Status

After all the ports are connected, verify that the SCE 2000 is not in a Warning state.
To verify that the SCE 2000 is not in a warning state, complete the following steps:
Step 1 On the SCE 2000 Front panel, examine that the Status LED is flashing green.
Step 2 To display the operation status of the system, at the SCE 2000# prompt, type show system
operation-status and press Enter.
A message displaying the operation status of the system appears. If the system is operating in
order, the following message appears:
System Operation status is Operational.
EXAMPLE:
The following example displays a sample output where the LEDs appear red/orange:
SCE 2000#show system operation-status
System Operation status is Operational

Viewing the User Log Counters

View the user log for errors that occurred during the installation process.
To display the user log device counters, complete the following steps:
At the SCE 2000# prompt, type show logger device User-File-Log counters and
press Enter.
EXAMPLE:
The following example shows the current User-File-Log device counters.
SCE 2000#show logger device user-file-log counters
Logger device User-File-Log counters:
Total info messages: 1
Total warning messages: 0
Total error messages: 0
Total fatal messages: 0
If there are “Total error messages” or “Total fatal messages”, use the show logger device
User-File-Log command to display details about the errors.