Monitor Mode
WiBox2100E User Guide 76
Command Command Name Function
SC Send Configuration Sets configuration of un it from hex records.
PI x.x.x.x Ping Pings unit with IP address x.x.x.x to check device
status.
AT ARP Table Shows the unit’s ARP table entries.
TT TCP Connection
Table
Shows all incoming and outgoing TCP connections.
NC Network Connection Shows the unit’s current IP address.
RS Reset Resets the unit.
QU Quit Exits diagnostics mode.
G0, G1, ....,Ge, Gf Get configuration
from memory page
Gets a memory page of configuration information
from the device.
S0, S1,...,Se, Sf Set configuration to
memory page
Sets a memory page of configuration information
on the device.
GM Get MAC address Shows the unit's 6-byte MAC.
SS Set Security record Sets the Security record without the encryption key
and length parameters. The entire record must still
be written, but the encryption-specific bytes do not
need to be provided (they can be null since they
are not overwritten).
Responses to some of the commands are given in Intel Hex format.
Note: Entering any of the commands listed above generates one of the
following command response codes:
Table 9-2. Command Response Codes
Response Meaning
0> OK; no error
1> No answer from remote device
2> Cannot reach remote device or no answer
8> Wrong parameter(s)
9> Invalid command