![](/images/new-backgrounds/1110185/110185105x1.webp)
Setup Mode: Channel Configuration
Note: All bit positions in the table that are blank represent “don’t care” bits for that particular option; they can be set to either a 0 or 1 value.
Table 7-5. Connect Mode Options
Connect Mode Option | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|
|
|
|
|
|
|
|
|
a) Incoming Connection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Never accept incoming | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accept with DTR Active | 0 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Always Accept | 1 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
b) Response
Nothing (quiet) |
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Character response (C=connect, |
|
|
|
| 1 |
|
|
|
|
D=disconnect, N=unreachable) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
c) Active Startup |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No active startup |
|
|
|
|
| 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
With any character |
|
|
|
|
| 0 | 0 | 0 | 1 |
|
|
|
|
|
|
|
|
|
|
With DTR Active |
|
|
|
|
| 0 | 0 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
With a specific start character |
|
|
|
|
| 0 | 0 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
Manual connection |
|
|
|
|
| 0 | 1 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
Autostart |
|
|
|
|
| 0 | 1 | 0 | 1 |
|
|
|
|
|
|
|
|
|
|
Hostlist | 0 | 0 | 1 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
d) Datagram Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Directed UDP |
|
|
|
|
| 1 | 1 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
e) Modem Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No Echo |
|
| 0 | 0 |
|
| 1 | 1 |
|
|
|
|
|
|
|
|
|
|
|
Data Echo & Modem Response |
|
| 0 | 1 |
|
| 1 | 1 | 1 |
(Numeric) |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Data Echo & Modem Response |
|
| 0 | 1 |
|
| 1 | 1 | 0 |
(Verbose) |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Modem Response Only (Numeric) |
|
| 0 | 0 |
| 1 | 1 | 1 | 1 |
|
|
|
|
|
|
|
|
|
|
Modem Response Only (Verbose) |
|
| 0 | 0 |
| 1 | 1 | 1 | 0 |
|
|
|
|
|
|
|
|
|
|
WiBox2100E User Guide | 53 |