8: Setup Mode: Advanced Settings
Expert Settings (Option 5)
Note: You can change these settings using Telnet or serial connections only, not
Caution: Only an expert should change these parameters. You must definitely know the consequences the changes may have.
Figure 8-1. Expert Settings
The default settings are listed below:
TCP Keepalive time in s | 45 |
(1s – 65s; 0s=disable) |
|
ARP Cache timeout in s | 600 |
(1s – 600s) |
|
|
|
CPU Performance | Regular |
|
|
Disable Monitor Mode @ bootup | N (No) (resulting in Monitor Mode enabled) |
|
|
HTTP Port Number | 80 |
| |
|
|
SMTP Port Number | 25 |
| |
MTU Size (512 – 1400) | 0 (resulting in an operational value of 1400) |
|
|
Enable alternate MAC | Disabled (OEM use only) |
|
|
Ethernet connection type | 0 (resulting in |
|
|
TCP Keepalive time in seconds
This option allows you to change how many seconds the unit waits during a silent connection before attempting to see if the currently connected network device is still on the network. If the unit gets no response, it drops that connection. The default setting is 45.
TCP Keepalive time in s (1s – 65s; 0s=disable): (45)? _
WiBox2100E User Guide | 67 |