Lantronix Ethernet manual Flush Mode Buffer Flushing, Pack Control

Models: Ethernet

1 92
Download 92 pages 13.42 Kb
Page 61
Image 61

Setup Mode: Channel Configuration

(3)The TCP connection closes even if the remote site does not acknowledge the disconnection.

(4)When there is a network connection to or from the serial port, the state LED turns off instead of blinking.

(5)When Ctrl+D or Hex 04 is detected, the connection is dropped. Both EOT must be enabled for Disconnect with EOT to function properly. the serial port to the network.

Telnet Mode and Disconnect with Ctrl+D is only detected going from

(6)When DTR transitions from a high state to a low state, the network connection to or from the serial port drops.

Flush Mode (Buffer Flushing)

Using this parameter, you can control line handling and network buffers with connection startup and disconnect. The default setting is 00.

FlushMode (00) ? _

You can also select between two different packing algorithms.

Note: All bit positions in the table that are blank represent “don’t care” bits for that particular option; they can be set to either a 0 or 1 value.

Table 7-8. Flush Mode Options

Function

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

Input Buffer (Serial to Network)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the device to the network

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the network to the device

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear when the network connection to or from the device is disconnected

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Buffer (Network to Serial)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the device to the network

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the network to the device

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Clear when the network connection to or from the device is disconnected

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Alternate Packing Algorithm (Pack Control)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pack Control

The packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters, while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream.

Pack control settings are enabled in Flush Mode. Set this value to 00 if you do not need specific functions.

Note: All bit positions in the table that are blank represent “don’t care” bits for that particular option; they can be set to either a 0 or 1 value.

WiBox2100E User Guide

61

Page 61
Image 61
Lantronix Ethernet manual Flush Mode Buffer Flushing, Pack Control