Lantronix Ethernet manual Endpoint Configuration, Common Options

Models: Ethernet

1 92
Download 92 pages 13.42 Kb
Page 38
Image 38

Web-Manager Configuration

 

 

character is received from the serial port.

 

 

With Active Mdm Ctrl In: Accepts external connection

 

 

requests only when the modem_control_in input is asserted.

 

 

With Start Character: Attempts to connect when it receives a

 

 

specific start character from the serial port. The default start

 

 

character is carriage return.

 

 

Manual Connection: Attempts to connect when directed by a

 

 

command string received from the serial port.

 

 

Auto Start: Automatically connects to the remote IP address

 

 

and port after booting up.

 

 

 

 

Start Character

If Active Connect is set to With Start Character, enter the

 

 

start character in this field. The default setting is 0D.

 

 

 

 

Modem Mode

Indicates the on-screen response type when in Modem Mode

 

 

(if Modem Mode is enabled). The default setting is None.

 

 

 

Endpoint Configuration

 

 

Local Port

Enter the local port number.

 

 

 

 

Auto increment local

Select to auto-increment the local port number for new

 

port number

outgoing connections. The range of auto-incremented port

 

 

numbers is 50,000 to 59,999 and loops back to the beginning

 

 

when the maximum range is reached. Disabled by default.

 

 

 

 

Remote Port

Enter the remote port number.

 

 

 

 

Remote Host

Enter the IP address of the remote device.

 

 

 

Common Options

 

 

Telnet Mode

This field is available for configuration only when Active

 

 

Connection is not set to None. Select Enable to permit

 

 

Telnet communication to the WiBox unit.

 

 

 

 

Terminal Name

This field is available for configuration only when Telnet Mode

 

 

is Enable.

 

 

Use the terminal name for the Telnet terminal type. Enter only

 

 

one name. When this option is enabled, the unit also reacts to

 

 

the EOR (End Of Record) and binary options, which can be

 

 

used for applications such as terminal emulation to IBM hosts.

 

 

 

 

Connect Response

A single character is transmitted to the serial port when there

 

 

is a change in connection state. The default setting is None.

 

 

 

 

Use Hostlist

If this option is set to True, the device server scrolls through

 

 

the hostlist until it connects to a device listed in the hostlist

 

 

table. Once it connects, the unit stops trying to connect to any

 

 

others. If this connection fails, the unit continues to scroll

 

 

through the table sequentially until it is able to connect to

 

 

another IP in the hostlist.

 

 

The hostlist is disabled for Manual Mode and for Modem

 

 

 

WiBox2100E User Guide

38

Page 38
Image 38
Lantronix Ethernet manual Endpoint Configuration, Common Options