Lantronix Ethernet DisConnTime Inactivity Timeout, Packing Interval, Trailing Characters, Option

Models: Ethernet

1 92
Download 92 pages 13.42 Kb
Page 62
Image 62

Setup Mode: Channel Configuration

Table 7-9. Pack Control Options

 

 

 

 

 

 

 

 

 

 

 

 

 

Option

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

Packing Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 12 msec

 

 

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

Interval: 52 msec

 

 

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

Interval: 250 msec

 

 

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

Interval: 5 sec

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

Trailing Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

One

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

 

 

Two

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

 

 

Send Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Byte Send Character Sequence

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Immediately After Send chars

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Interval

Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is between successive network segments containing data. For alternate packing, the default interval is 12 ms.

Trailing Characters

In some applications, CRC, Checksum, or other trailing characters follow the end-of- sequence character; this option helps to adapt frame transmission to the frame boundary. The default setting is 00 (none).

Send Characters

‹If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2-byte sequence; if this option is not enabled, the unit interprets them independently. The default setting is 0 (disabled).

‹If Send Immediately After Characters is not set, any characters already in the serial buffer are included in the transmission after a "transmit" condition is found. If this option is set, the unit sends immediately after recognizing the transmit condition (sendchar or timeout). The default setting is 0.

Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.

DisConnTime (Inactivity Timeout)

Use this parameter to set an inactivity timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds.

WiBox2100E User Guide

62

Page 62
Image 62
Lantronix Ethernet manual DisConnTime Inactivity Timeout, Packing Interval, Trailing Characters, Send Characters, Option