4.3.1Identify Device command

The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 7 on page 30. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.

The following commands contain drive-specific features that may not be included in the Serial ATA specifica- tion.

Word

Description

Value

 

 

 

 

Configuration information:

0C5AH

 

• Bit 15: 0 = ATA; 1 = ATAPI

 

0

• Bit 7: removable media

 

 

• Bit 6: removable controller

 

 

• Bit 0: reserved

 

 

 

 

1

Number of logical cylinders

16,383

 

 

 

2

ATA-reserved

0000H

 

 

 

3

Number of logical heads

16

 

 

 

4

Retired

0000H

 

 

 

5

Retired

0000H

 

 

 

6

Number of logical sectors per logical track: 63

003FH

 

 

 

7–9

Retired

0000H

 

 

 

10–19

Serial number: (20 ASCII characters, 0000H = none)

ASCII

 

 

 

20

Retired

0000H

 

 

 

21

Retired

0400H

 

 

 

22

Obsolete

0000H

 

 

 

23–26

Firmware revision (8 ASCII character string, padded with blanks to

x.xx

 

end of string)

 

 

 

 

27–46

Drive model number: (40 ASCII characters, padded with blanks to end

 

 

of string)

 

 

 

 

47

(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write

8010H

 

multiple (16)

 

 

 

 

48

Reserved

0000H

 

 

 

49

Standard Standby timer, IORDY supported and may be disabled

2F00H

 

 

 

50

ATA-reserved

0000H

 

 

 

51

PIO data-transfer cycle timing mode

0200H

 

 

 

52

Retired

0200H

 

 

 