12U Series CE Family Product Manual, Rev. A
1.8.3 Humidity |
| |
1.8.3.1 | Relative Humidity | |
Operating |
| 5% to 90% noncondensing (30% per hour max) |
Nonoperating | 5% to 95% noncondensing (30% per hour max) | |
1.8.3.2 | Wet bulb temperature | |
Operating |
| 29.4°C (84°F) max |
Nonoperating | 40.0°C (104°F) max | |
1.8.4 Altitude |
| |
Operating |
| |
Nonoperating |
1.8.5 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may be applied in the X, Y or Z axis.
1.8.5.1 Operating shock
These drives comply with the performance levels specified in this docu- ment when subjected to a maximum operating shock of 63 Gs (based on
1.8.5.2 Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subse- quently put into operation is 350 Gs (based on nonrepetitive
1.8.6 Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive mounting screws. Vibration may be applied in the X, Y or Z axis.