2.11Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea- surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.

Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:

(Number of seeks per second = 0.4 / (average latency + average access time)

Table 4:

Drive level acoustics

 

 

 

 

Acoustic mode

 

 

 

 

 

 

Idle*

 

Quiet Seek

Performance Seek

 

 

 

 

2.3 bels (typ)

 

2.5 bels (typ)

3.0 bels (typ)

2.5 bels (max)

2.7 bels (max)

3.2 bels (max)

 

 

 

 

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.

2.12Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 5:

Electromagnetic immunity

 

 

 

 

 

 

 

 

 

 

Performance

Reference

Test

 

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200

 

 

 

 

Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1

A

EN 61000-4-6: 97

 

 

kHz sine

 

 

 

 

 

 

Voltage dips, interrupts

0% open, 5 seconds

C

EN 61000-4-11: 94

 

 

0% short, 5 seconds

C

 

 

 

40%, 0.10 seconds

C

 

 

 

70%, 0.01 seconds

B

 

 

 

 

 

 

Momentus 42 Product Manual, Rev. A