REMOVABLE KNOBS
All control knobs may be removed for easy cleaning by pulling the knob straight off the stem. Be sure that the knob is in the OFF position before removal.
Hint: Slip a thin cloth (such as a handkerchief) or a piece of string under and around the knob edge and pull up.
Caution: Read these instructions carefully be-
fore replacing the knobs. Replacing the knobs improperly will damage the knobs and the spring clip on the stems, if this happens, the knobs will
fit loosely,
To replace the knob:
1.The knob stem has a groove tn each side. The groove on one side has a spring clip. The other groove is clear (see illustration).
2_ Check the inside of the knob and find the molded rib.
3.Replace the knob by fitting the molded rib Inside the knob Into the clear groove on the stem.
MOLDED
RIB
CLEAR GROOVE
IN STEM
Note: Be sure to replace knobs on correct stems from which they came.
ANTSoT IP DEVICE
if your range is removed for cleaning, servicing or any reason, be sure anti.
tip device is re.engaged properly
when the range is replaced. Fa_llure to take this precaution could result in tipping of the range and cause injury.
When replacing the range:
1.Hook the loose end of the chain onto the bracket by slipping the nearest link of the chain into the slot in the bracket, making sure the chain is pulled as tight as possible and that there is no excess slack in the chain after chain is attached to the bracket.
. Excess slack in the chain could allow the range to tip over.
2_ Slide the range all the way back into the counter. Oncethe range is pushed back tn place, there will be a small amount of slack in the chain. This is normal.
NOTE: To insure the device Is installed and
gaged properly, carefully try to tip the range forward. The device should secure the range and not allow it to tip.
iRD
BRACKET...
OPTIONAL
LOCATION
CHAIN "_
BRACKET/
FACTORY
e
LOCATION
(Electric model shown; Opposite side used for Gas models)