Wiring Diagram:
Bond Status Sensor:
The Bond Status Sensor checks to make sure the door is closed, and the electromagnet is locked.
LED Indicators:
Green | Door is closed and locked |
Red | Door not closed and/or locked |
Off | Door in use / No power |
600PQ and 1K2P models ONLY
*NOTE: Connect switching devices like
(600PQ and 1K2P
models ONLY)
Voltage Selection Jumpers
Position two jumpers | Position a jumper over |
on all four pins for | the two middle pins for |
12VDC operation | 24VDC operation |
Control |
Device* |
Power Supply
Maximum Distance from Power Source to Electromagnetic Lock:
For a complete chart, please visit
12VDC Minimum Wire Gauge:
| Wire Length | 25ft. | 50ft. | 75ft. | 100ft. | 150ft. | 200ft. | 250ft. | 300ft. | 400ft. | 500ft. | 1000ft. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Wire Gauge @ 500mA | 20 |
| 18 | 18 | 18 | 16 |
| 14 |
| 14 |
| 12 |
| 10 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24VDC Minimum Wire Gauge: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| Wire Length | 25ft. | 50ft. | 75ft. | 100ft. | 150ft. | 200ft. | 250ft. | 300ft. | 400ft. | 500ft. | 1000ft. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Wire Gauge @ 250mA | 24 |
| 24 | 22 | 20 | 18 |
| 18 |
| 16 |
| 16 |
| 14 | 14 | 14 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note:
Optional
| Does not include armature plate |
|
|
|
| |
Description | “Z” Brackets | “L” Brackets | Plate Spacers | Glass Door | Armature | |
(includes 1 “L” Bracket) | “U” Brackets | Plate Holders | ||||
|
|
| ||||
|
|
|
|
|
| |
Models |
|
|
|
|
| |
Models | ||||||
|
|
|
|
| ||
Additional |
|
|
| |||
|
|
| ||||
Models |
| (for |
|
| ||
for |
|
|
| |||
|
|
|
|
|
Note: Brackets and spacers are not available for
7 |