Specifications

In compliance with (EM)

Europe:

USA:

Approved by

Canada:

Mains unit*

Input voltage

Power/current consumption Output voltage Secondary output current Temperature range

*depending on country variant

In compliance with

Europe:

USA:

Canada:

Certified by cCSAus KL, 60065, CSA.

 

EMC

EN 301489-1/-9

 

Radio

EN 300422-1/-2

 

Safety

EN 60065

 

 

47 CFR 15 subpart B

 

 

 

 

 

Industry Canada

RSS 210,

IC: 2099A-G3EM100

 

 

 

 

 

NT 2–1

 

NT 2–3

 

 

 

110 V~ or 230 V~,

100 to 240 V~,

 

50/60 Hz

 

50/60 Hz

 

 

 

 

 

9 VA

 

max. 120 mA

 

13 V

 

12 V

 

300 mA

 

400 mA

 

–10 °C to +40 °C

 

–10 °C to +40 °C

EMC

NT 2-3: EN 55022, EN 55024,

 

EN 55014-1/-2

 

NT 2-1: EN 55013, EN 55020,

 

EN 55014-1/-2

Safety

EN 60065

47 CFR 15 subpart B

ICES 003

For accessories and information on connector assignment, visit the ew G3 product page at www.sennheiser.com.

SK 100 and SKM 100

RF characteristics

Modulation

wideband FM

Frequency ranges

516–558, 566–608, 626–668, 734–776,

 

 

780–822, 823–865 MHz (A to E, G, see page 4)

Transmission frequencies

 

 

1,680 frequencies, tuneable in steps of 25 kHz

 

 

20 frequency banks, each with up to 12 factory-

 

 

preset channels, intermodulation-free

 

 

 

 

 

1 frequency bank with up to 12 user programmable

 

 

channels

Switching bandwidth

 

 

 

42 MHz

Nominal/peak deviation

 

 

 

±24 kHz / ±48 kHz

Frequency stability

 

 

 

±15 ppm

RF output power at 50 Ω

 

 

 

typ. 30 mW

Pilot tone squelch

 

 

 

can be switched off

32