Specifications
In compliance with (EM)
Europe:
USA:
Approved by
Canada:
Mains unit*
Input voltage
Power/current consumption Output voltage Secondary output current Temperature range
*depending on country variant
In compliance with
Europe:
USA:
Canada:
Certified by cCSAus KL, 60065, CSA.
| EMC | EN | |
| Radio | EN | |
| Safety | EN 60065 |
|
| 47 CFR 15 subpart B |
| |
|
|
|
|
Industry Canada | RSS 210, | IC: | |
|
|
|
|
| NT |
| NT |
|
|
| |
110 V~ or 230 V~, | 100 to 240 V~, | ||
| 50/60 Hz |
| 50/60 Hz |
|
|
|
|
| 9 VA |
| max. 120 mA |
| 13 V |
| 12 V |
| 300 mA |
| 400 mA |
|
|
EMC | NT |
| EN |
| NT |
| EN |
Safety | EN 60065 |
47 CFR 15 subpart B
ICES 003
For accessories and information on connector assignment, visit the ew G3 product page at www.sennheiser.com.
SK 100 and SKM 100
RF characteristics
Modulation | wideband FM | |
Frequency ranges | ||
|
| |
Transmission frequencies |
|
|
1,680 frequencies, tuneable in steps of 25 kHz | ||
|
| 20 frequency banks, each with up to 12 factory- |
|
| preset channels, |
|
|
|
|
| 1 frequency bank with up to 12 user programmable |
|
| channels |
Switching bandwidth |
|
|
| 42 MHz | |
Nominal/peak deviation |
|
|
| ±24 kHz / ±48 kHz | |
Frequency stability |
|
|
| ≤±15 ppm | |
RF output power at 50 Ω |
|
|
| typ. 30 mW | |
Pilot tone squelch |
|
|
| can be switched off |
32