Product overview ADN PS power supply
Product overview ADN PS power supply
1 | 2 | 3 | 4 | 5 | 1 |
ADN PS
PORT I | PORT II | DATA | ||
|
|
| CU/PS | PS |
1 | 2 | 1 | 2 |
|
100 - 50/60Hz 385W
PORT & PORT II: max. 5. sum
6 7 8 9 0 | A | B | C | |
D | E | |||
|
| |||
|
|
| 15 |
A Front view
1Rack mount “ears”
2On/off switch
3PORT I status LED for outputs 1 and 2
4PORT II status LED for outputs 1 and 2
5POWER status LED
Overview of the status LEDs
B Rear view
6PORT I socket – output 1 (RJ45) for connection of conference units
7PORT I socket – output 2 (RJ45) for connection of conference units
8PORT II socket – output 1 (RJ45) for connection of conference units
9PORT II socket – output 2 (RJ45) for connection of conference units
<DATA CU/PS input socket (RJ45) for connection of ADN CU1 central unit or ADN PS power supply
ADATA PS output socket (RJ45) for connection of additional ADN PS
BFans
CMains socket
DHazard warnings
EType plate
Status LED | Color | Meaning |
|
|
|
POWER 5 | green | ADN PS is switched on |
|
|
|
PORT I 3/Port II 4 | – | Not used, switched off |
output 1/2 | orange | Conference units are connected in strings |
| ||
| green | Conference units are connected in redundant |
|
| ring topology via outputs 1 and 2 |
| flashing | Error in a cable string; |
| orange | output is switched off |
|
|
|
4 ADN PS