Structuring and controlling the conference system
Structuring and controlling the conference system
Structuring the conference system
The ADN conference system is suitable for conferences with up to 400 conference units. For safe operation of the conference system, make sure that all conference units are supplied with a voltage of at least 35 V! The voltage supplied depends on the number of connected conference units and on the cable lengths. The standard cable length between the central unit or power supply and the first conference unit is 80 m max. and the standard cable length between the individual conference units is 2 to 5 m.
If these cable lengths are observed, safe operation of conference systems with the following number of conference units is ensured:
•small conference systems comprising only an ADN CU1 central unit
–
•large conference systems comprising an ADN CU1 central unit and a max. of 15 ADN PS power supplies
–max. 400 conference units connected in simple strings or in ring topology
per ADN PS power supply
–
–
If cable lengths are shorter, it might be that more conference units can be used.
ADN D1 delegate units and ADN C1 chairperson units can be combined in an arbitrary order. The number of chairperson units, however, is limited to 10 max. per conference system. All components of the conference system are interconnected using SDC CBL
Small conference system with simple cabling
For small conference systems with approx.
ADN CU1
PORT | II |
|
PORT I
ADN CU1
max. 80 m
52.8 V
max. 40
ADN D1/ADN C1
1 | 2 | 3 | ... | 20 | ||
| approx.. |
| approx.. |
|
| |
|
|
|
|
|
|
|
>35 V
ADN PS 5