Putting the receiver into operation
CAUTION! | Risks when rack mounting the receiver! |
When installing the device in a closed or
Make sure that the ambient temperature within the rack does not exceed the permissible temperature limit specified in the specifications (see page 51).
Ensure sufficient ventilation; if necessary, provide additional ventila- tion.
Make sure that the mechanical loading of the rack is even.
When connecting to the power supply, observe the information indi- cated on the type plate. Avoid circuit overloading. If necessary, provide overcurrent protection.
When rack mounting, please note that intrinsically harmless leakage currents of the individual mains units may accumulate, thereby exceeding the allowable limit value. As a remedy, ground the rack via an additional ground connection.
Rack mounting To mount the receiver into a rack, you require the GA 3 rack adapter (see one receiver “Accessories and spare parts” on page 49):
Secure the rack mount “ears” of the GA 3 rack adapter to the receiver in the same way as described for the stacking elements (see page 11).
Secure the blanking plate of the GA 3 rack adapter to one of the rack mount “ears” using two recessed head screws (M 6x10).
14