SMC sierra monitor corporation Sentry Instruction Manual - Version 6
Nitric Oxide (5100-19)
Range: Factory 20 PPM, Max 100 PPM
Operating Temperature 4oF to 122oF (-20oC to 50oC)
Relative Humidity 15 - 99% RH
Response: <15 seconds to 90% indication
Calibration Frequency 90 Days, Recommended
Zero Drift: Less than 2% per month
Typical Life: 3 years in normal service
Warranty: 1 year
Hydrogen Chloride (5100-21)
Range: Factory 20 PPM, Max 100 PPM
Operating Temperature 4oF to 122oF (-20oC to 50oC)
Relative Humidity 15 - 99% RH
Response: <100 seconds to 90% indication
Calibration Frequency 90 Days, Recommended
Zero Drift: Less than 1% per month
Typical Life: 2 years in normal service
Warranty: 1 year
Hydrogen Cyanide (5100-22)
Range: Factory 20 PPM, Max 200 PPM
Operating Temperature 4oF to 122oF (-20oC to 50oC)
Relative Humidity 15 - 99% RH
Response: <70 seconds to 90% indication
Calibration Frequency 90 Days, Recommended
Zero Drift: Less than 1% per month
Typical Life: 2 years in normal service
Warranty: 1 year
Ammonia (5100-25)
Range: Factory 50 PPM, Max 50 PPM
Relative Humidity 20 - 90% RH
Operating Temperature 14oF to 113oF (-10oC to 45oC)
Response: <30 seconds to 90% indication
Calibration Frequency 90 Days, Recommended
Zero Drift: Less than 2% per month
Typical Life: 2 - 3 years in normal service
Warranty: 1 year
Ethylene Oxide (5100-27)
Range: Factory 20 PPM, Max 100 PPM
Relative Humidity 5 - 99% RH
Operating Temperature 4oF to 122oF (-20oC to 50oC)
Response: <90 seconds to 90% indication
Calibration Frequency 90 Days, Recommended
Zero Drift: Less than 2% per month
Typical Life: 2 years in normal service
Warranty: 1 year