27
Appendix B: Preset StandardCone-Fire Schedules - °C

These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your

changes. Then load your new schedule into Ramp-Hold.

Low Fire Cones °C

Segment 1 Segment 2
Cone Rate 1 Temp. 1 Rate 2 Temp. 2
022 220 526 60 586
021 220 540 60 600
020 220 566 60 626
019 220 618 60 678
018 220 655 60 715
017 220 678 60 738
016 220 712 60 772
015 220 731 60 791
014 220 747 60 807
013 220 777 60 837
012 220 801 60 861
011 220 815 60 875

Medium Fire Cones °C

Segment 1 Segment 2 Segment 3 Segment 4
Cone Rate 1 Temp. 1 Rate 2 Temp. 2 Rate 3 Temp. 3 Rate 4 Temp. 4
010 180 550 85 600 100 843 60 903
09 180 550 85 600 100 860 60 920
08 180 550 85 600 100 882 60 942
07 180 550 85 600 100 916 60 976
06 180 550 85 600 100 938 60 998
05 180 550 85 600 100 971 60 1031
04 180 550 85 600 100 1003 60 1063
03 180 550 85 600 100 1026 60 1086
02 180 550 85 600 100 1042 60 1102
01 180 550 85 600 100 1059 60 1119

High Fire Cones °C

Segment 1 Segment 2 Segment 3 Segment 4
Cone Rate 1 Temp. 1 Rate 2 Temp. 2 Rate 3 Temp. 3 Rate 4 Temp. 4
1 180 550 100 600 90 1017 60 1137
2 180 550 100 600 90 1022 60 1142
3 180 550 100 600 90 1032 60 1152
4 180 550 100 600 90 1042 60 1162
5 180 550 100 600 90 1066 60 1186
6 180 550 100 600 90 1102 60 1222
7 180 550 100 600 90 1119 60 1239
8 180 550 100 600 90 1129 60 1249
9 180 550 100 600 90 1140 60 1260
10 180 550 100 600 90 1165 60 1285