Setting Callback dial strings

The Sentry integrated Modem supports definition of up to 30 callback dial strings.

The AT&Z command is used to set a dial string. Dial strings may be up to 34 characters and may include other AT commands.

To set a Callback dial string:

After successfully logging into the modem with the Setup password, type at&z, followed by the memory location (0-29), =at, dt (tone-dial) or dp (pulse-dial) and the number/dial string. Press Enter.

Examples

The following command sets the dial string for memory location 0 to tone-dial, 1-775-284-2000:

at&z0=atdt17752842000<Enter>

The following command sets the dial string for memory location 29 to pulse-dial, 1-775-555-1212:

at&z29=atdp17755551212<Enter>

To verify and reset the modem with the configured dial strings:

Type at&v and press Enter.

Type atz and press Enter.

NOTE: Callback Security dial strings may also be configured to allow a user to bypass the stored number with a dynamic entry or make a direct connection without a callback. Server Technology does not recommend the use of these options as they have a negative effect on security for the modem connection.

To enable these options additional characters are required when setting a dial string:

+enables optional dynamic callback dial string entry

-enables optional direct connection without a callback

,??? Used with ‘+’ enables optional use of dynamic extension entry

Examples

The following command enables dynamic callback string and extension entry where the extension length is 5 characters:

at&z0=+atdt17752842000,?????<Enter>

The following command enables direct connection without a callback:

at&z0=-atdp17755551212<Enter>

Resetting a Callback memory location

The AT#CBR command is used to reset the dial string and password for any given memory location.

To reset a Callback memory location:

After successfully logging into the modem with the Setup password, type at#cbr, followed by the memory location (0-29), and press Enter.

Type atz and press Enter to reset the modem with the new settings.

Example

The following commands reset memory location 0:

at#cbr0<Enter>

OK atz<Enter>

OK

8 • Operations

Sentry Global Security Modem

 

Installation and Operations Manual