VACANCY OPERATION
Heating operation with 10°C set temperature will be performed to protect your home and furniture from frost damage, even when you are out.
1 Press the HEAT button.
2 Press the VACANCY button.
• The remote control will display “ 10°C ”.
1
2
TO CANCEL
Press the VACANCY button again.
ADDITIONAL NOTES ON
OPERATION
OPERATING TEMPERATURE RANGE
|
| INDOOR TEMP. | OUTDOOR TEMP. | |
HEATING | upper limit | 27˚C | 24˚C | |
lower limit | – | |||
| ||||
COOLING | upper limit | 32˚C | 43˚C | |
lower limit | 21˚C | |||
|
•The
•Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This unit has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re- start in the same settings which were active before the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
•When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic
•After
HEATING EFFICIENCY
•The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.
•If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
•It takes time to warm up and heat the entire room because of the forced air circulation system.
13