Ingersoll-Rand IRN100-200H-2S, IRN37-160K-CC 4ATT SENSOR, Package AIR Discharge Temperature 4CTT

Models: IRN50-200H-CC IRN37-160K-CC IRN75-160K-2S IRN250-300H-2S IRN100-200H-2S

1 100
Download 100 pages 58.63 Kb
Page 59
Image 59

8.0 GENERAL INFORMATION

KEY

1ATS

SWITCH, HIGH AIR END DISCHARGE

 

TEMPERATURE

1DPS

SWITCH, FOULED OIL FILTER

1VAC

SWITCH, FOULED AIR FILTER

1ATT

SENSOR, AIREND INLET

2ATT

SENSOR, AIREND DISCHARGE TEMPERATURE

2CTT

SENSOR, INJECTED COOLENT TEMPERATURE

3APT

TRANSDUCER, SUMP PRESSURE, WET SIDE

3SV

VALVE, BLOWDOWN SOLENOID

4APT

TRANSDUCER, PACKAGE AIR DISCHARGE

 

PRESSURE

4ATT

SENSOR, PACKAGE AIR DISCHARGE

 

TEMPERATURE

4CTT

SENSOR, OIL COOLER OUT TEMPERATURE

4SV

VALVE, WATER STOP SOLENOID (W/C ONLY)

6APT

TRANSDUCER, SUMP AIR PRESSURE, DRY SIDE

9APT

TRANSMITTER, REMOTE AIR PRESSURE

 

(OPTIONAL)

9SV

VALVE, CONDENSATE DRAIN

11SV

VALVE, ANTI-CONDENSATION SOLENOID

AT

AUTOTRANSFORMER (IF FITTED)

AW1

AUXILIARY WARNING 1

AW2

AUXILIARY WARNING 2

BP

BACKPLATE

CCAPACITOR

CAB CABINET

CDE

CONDENSATE DRAIN ERROR

CDV

CONDENSATE DRAIN VALVE (IF FITTED)

CFO

COMMON FAULT OUTPUT

CK

CHOKE

EXC

EXTERNAL COMMUNICATIONS

DR

DRIVE

DVF

FAN, DRIVE BOX VENTILATION

EB

EARTH BAR

ES

SWITCH, EMERGENCY STOP

FD

DRIVE, BLOWER (A/C ONLY)

FM

MOTOR, BLOWER

GND

GROUND

HTR1

HEATER, SPACER 25 WATTS

HTR2

HEATER, SPACER 25 WATTS

K1

RELAY, RUN

K2

RELAY, FAULT

KM1

CONTACTOR, MAIN MOTOR

KM4

CONTACTOR, FAN MOTOR (W/C ONLY)

KM5

CONTACTOR, DRIVE VENTILATION FAN

MCB1

BREAKER, MINIATURE CIRCUIT, TRANSFORMER

MCB2

BREAKER, MINIATURE CIRCUIT, DVF

MCB3

BREAKER, MINIATURE CIRCUIT, VFD SUPPLY

MCB4

BREAKER, MINIATURE CIRCUIT, VFD SUPPLY

MCB5

BREAKER, MINIATURE CIRCUIT, PSU

MCB9

BREAKER, MINIATURE CIRCUIT, HEATERS

MF

MAINS FILTER (IF FITTED)

MM

MOTOR, MAIN

MMS

BREAKER, FAN MOTOR

OPT

OPTIONAL

OV

ZERO VOLTAGE

PE

PROTECTED EARTH

PORO

POWER OUTAGE RESTART OPTION (OPTIONAL)

PSU

POWER SUPPLY UNIT

RFI

FILTER, RADIO FREQUENCY INTERFERENCE

RSP

REMOTE STOP

RST

REMOTE START

SGNE

CONTROLLER, INTELLISYS

SL

SERIAL LINK

SS1-3

RELAY, SOLID STATE

ST

SERVICE TOOL

T1

TRANSFORMER, CONTROL

TH

THERMOSTAT

TRR

TRUE RUNNING

WR

GENERAL WARNING

COLOR

 

BLK

BLACK

BLU

BLUE

BRO

BROWN

GRE

GREEN

PIN

PINK

RED

RED

SCR

SCREEN

VIO

VIOLET

WHI

WHITE

YEL

YELLOW

Wires

Numbers

Function

Wire color

1−99

Power

Black

100−199

AC Control

Red

200−299

DC Control

Blue

300−399

Auxiliary

Orange

NOTES:

1.FACTORY SUPPLIED AS SHOWN BY CONNECTION TO OUTPUT OF CONTROL TRANSFORMER T1. WIRE NUMBER

100& 121.

2.ALTERNATIVELY THE SUPPLY MAY BE TAKEN FROM AN

INDEPENDENT SOURCE: IN THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE DISCONNECTED.

3.ENSURE PARALLEL CONNECTION OF HEATERS.

NOTES:

1.CONNECTIONS FOR USE ON 200/230V SYSTEMS. THE SUPPLY IS INDEPENDENT OF THE MAIN COMPRESSOR. THE CUSTOMER MUST PROVIDE AN ISOLATOR / DISCONNECT SWITCH ADJACENT TO THE MACHINE FOR THIS SUPPLY. IN THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE DISCONNECTED.

2.ENSURE SERIES CONNECTION OF HEATERS.

IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S

57

http://air.irco.com

 

Page 59
Image 59
Ingersoll-Rand IRN100-200H-2S, IRN37-160K-CC, IRN250-300H-2S manual 4ATT SENSOR, Package AIR Discharge Temperature 4CTT