11.0 FAULT FINDING

SYMPTOM

 

FAULT

REMEDY

Pressure produced

 

Intellisys set incorrectly

Check and modify settings

by compressor is too

 

Pressure transducer may be

Recalibrate or replace

highcompressor is too high

 

 

faulty, incorrectly calibrated or

 

due to speed not reducing as

 

 

 

not receiving pressure signal

 

demand reducesreduces

 

 

 

Drive settings fault

Contact your local IR representative

 

 

Compressor discharge air too

 

High ambient temperature

Review installation and system parameters

hot

 

Insufficient cooling air

Check ducting and cooling air path, check

 

 

 

 

 

direction of blower rotation

 

 

Blocked aftercooler matrix

Clean or replace

Compressor package produces

 

Panels or doors are not closed

Rectify fault

excessive noise

 

properly

 

 

 

Air leaks from internal pipework /

Overhaul or replace

 

 

components

 

 

 

Blower or blower motor bearings

Overhaul or replace

 

 

worn

 

 

 

Loose debris impacting on

Remove and rectify any damage

 

 

blower during rotation

 

 

 

Blowdown valve stuck open

Overhaul or replace

 

 

Pressure relief valve not seating

Overhaul or replace

 

 

correctly

 

 

 

Vibration due to motor, airend or

Overhaul or replace

 

 

blower imbalance

 

 

 

Airend requires overhaul

Contact your local IR representative

Discharge air is contaminated

 

Scavenge pipe is blocked, broken

Clean or replace

with coolantcoolant

 

or o−ring is not sealing

 

 

 

Separator element is punctured,

Replace

 

 

or incorrect, or requires changing,

 

 

 

or not sealing correctly

 

 

 

Incorrect coolant has been added

Drain system, check for damage. Clean, refill

 

 

 

with correct coolant.

 

 

System has been overfilled with

Check for damage, drain excess.

 

 

coolant

 