Ingersoll-Rand IRN37-160K-CC manual Sound pressure level dBA, Flow at 7.5 Barg m3/min, 25/12

Models: IRN50-200H-CC IRN37-160K-CC IRN75-160K-2S IRN250-300H-2S IRN100-200H-2S

1 100
Download 100 pages 58.63 Kb
Page 30
Image 30

8.0 GENERAL INFORMATION

N55K

N75K

N75H

N100H

General

Sound pressure level dB(A) *

75

 

75

75

 

75

Maximum ambient temperature ° C (° F)

46 (115)

 

46 (115)

46 (115)

 

46 (115)

Minimum ambient temperature ° C (° F)

1.7 (35)

 

1.7 (35)

1.7 (35)

 

1.7 (35)

Weight Kg (lbs)

1531 (3374)

 

1531 (3374)

1531 (3374)

 

1531 (3374)

Maximum pressure barg (psig)

10 (145)

 

10 (145)

10 (145)

 

10 (145)

Minimum pressure barg (psig)

4.5 (65)

 

4.5 (65)

4.5 (65)

 

4.5 (65)

Coolant capacity litres (US gal)

30 (8)

 

30 (8)

30 (8)

 

30 (8)

HAT switch setting ° C (° F)

120 (248)

 

120 (248)

120 (248)

 

120 (248)

Performance

 

 

 

 

 

 

Flow at 7.5 Barg (m3/min)

10.11

 

12.94

 

Flow at 8.5 Barg (m3/min)

9.29

 

12.15

 

Flow at 10 Barg (m3/min)

8.49

 

11.50

 

Flow at 100 psig (cfm)

 

372

 

479

Flow at 125 psig (cfm)

 

328

 

429

Flow at 140 psig (cfm)

 

306

 

413

Air Cooling System

 

 

 

 

 

 

Cooling air flow m3/min (cfm)

241 (8500)

 

241 (8500)

241 (8500)

 

241 (8500)

Maximum ΔP in air ducts Pa (inch WG)

124 (0.5)

 

124 (0.5)

124 (0.5)

 

124 (0.5)

Compressed air outlet ΔT° C (° F)

8 (15)

 

8 (15)

8 (15)

 

8 (15)

Water Cooling System

 

 

 

 

 

 

Cooling (clean) water flow l/min (US

51/38

 

95/46

51/38

 

95/46

gallon/min) @ 10 ° C (50 ° F) / 32 ° C (90

(13.5 /10)

 

(25 /12)

(13.5/10)

 

(25/12)

° F)

 

 

 

 

 

 

Maximum ΔP in air ducts Pa (inch WG)

62 (0.25)

 

62 (0.25)

62 (0.25)

 

62 (0.25)

Compressed air outlet ΔT ° C (° F)

14 (25)

 

14 (25)

14 (25)

 

14 (25)

 

 

 

 

 

 

 

Main Power Circuit A/C (W/C) ***

 

 

 

 

 

 

Package full load current at 220V (A) **

208 (196)

 

208 (196)

 

Package full load current at 400V (A) **

110 (104)

 

144 (138)

 

 

 

 

 

 

 

 

Package full load current at 460V (A) **

 

100 (94)

 

131 (125)

Package full load current at 575V (A) **

 

82 (78)

 

108 (103)

Max fuse size @ 220V (A)

300

 

400

300

 

400

 

 

 

 

 

 

 

Max fuse size @ 400V (A)

150

 

200

150

 

200

Max fuse size @ 460V (A)

150

 

200

150

 

200

Max fuse size @ 575V (A)

125

 

150

125

 

150

 

 

 

 

 

Fuse type

Fast acting class J, T or semiconductor type, current limiting

 

 

interrupt rating 200, 000 Amps RMS SYM.

 

Heater Circuit

 

 

 

 

 

 

110V Single Phase Rating (A)

4

 

4

4

 

4

 

 

 

 

 

 

 

230V Single Phase Rating (A)

4

 

4

4

 

4

Fuse type

 

 

General purpose

 

*In accordance with PNEUROP PN8NTC2.3

**Tolerances in accordance with ISO 1217

***Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)

28IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

Page 30
Image 30
Ingersoll-Rand IRN37-160K-CC, IRN50-200H-CC Sound pressure level dBA, Minimum ambient temperature C F Weight Kg lbs, 25/12