11.0 FAULT FINDING

SYMPTOM

 

FAULT

REMEDY

Discharge air is contaminated

 

Aftercooler not functioning correctly

Clean or replace

with condensate

 

 

 

Moisture separator drain trap faulty

Overhaul or replace

 

 

 

 

 

 

 

 

Continuous low speed / low ambient

Review system requirements and

 

 

operation causing condensate build

contact your local IR representative

 

 

up

 

Compressor package draws too

 

Compressor operating above rated

Check and modify settings. Review

much current

 

pressure

system requirements and contact your

 

 

 

local IR representative

 

 

Separator filter element dirty or

Replace

 

 

blocked

 

 

 

Voltage supply is low or unbalanced

Contact your local IR representative or a

 

 

 

qualified electrician

 

 

Airend is damaged

Contact your local IR representative

Excessive coolant consumption

 

Coolant system leak

Overhaul or replace

 

 

 

 

 

 

See also ‘discharge air is contaminated

See above

 

 

with coolant’

 

11.2 INTELLISYS FAULTS

(INDICATED ON THE INTELLISYS CONTROLLER)

FAULT

 

CAUSE

REMEDY

Emergency Stop

 

Emergency stop button has

Identify reason why, repair fault, disengage button

 

 

been pressed.

and reset Intellisys controller

Blower motor overload

 

Blower is blocked, damaged or

Remove blockage, repair or replace damaged

 

 

blower motor is faulty.

components

High airend discharge

 

Compressor operating above

Check and modify settings. Review system

temperature

 

rated pressure

requirements and contact your local IR

 

 

representative

 

 

 

 

 

Low coolant level

Check for leaks. See also ‘discharge air is

 

 

 

contaminated with coolant’. Top up coolant.

 

 

High ambient temperature

Review installation and system parameters

 

 

Insufficient cooling air

Check ducting and cooling air path.

 

 

Blocked coolant cooler matrix

Clean or replace

 

 

Blower motor direction of

Wire correctly

 

 

rotation incorrect

 

Check setpoints

 

Controller software has been

Recalibrate all sensors and check setpoints

 

 

changed

 

94IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

Page 96
Image 96
Ingersoll-Rand IRN250-300H-2S, IRN37-160K-CC manual See above, With coolant’, Remove blockage, repair or replace damaged