11.0 FAULT FINDING

SYMPTOM

 

FAULT

REMEDY

Compressor will not meet

 

Compressor not sized to

Contact your local IR representative

pressure required by system

 

meet system requirements or

 

 

 

requirements have been changed.

 

 

 

Air loss due to pipe, hose, joint or

Overhaul or replace

 

 

seal failure

 

 

 

Air loss due to blowdown valve stuck

Overhaul or replace

 

 

open

 

 

 

Air loss through pressure relief valve

Overhaul or replace

 

 

not seating or set incorrectly

 

 

 

Air loss due to moisture separator

Overhaul or replace

 

 

drain trap stuck open

 

 

 

Motor speed too low caused by drive

Contact your local IR representative

 

 

incorrectly set

 

 

 

Motor speed too low caused by fault

See section on drive faults

 

 

in drive settings

 

 

 

Intellysis controller fault

Overhaul or replace

 

 

Drive motor fault

See section on drive faults

 

 

Pressure transducer faulty,

Recalibrate or replace

 

 

incorrectly calibrated or EMF

 

 

 

interference

 

 

 

Incorrect Intellisys controller settings

Check and modify settings

 

 

Inlet grill or ducting is blocked

Check and clean

 

 

Air filter dirty or collapsed

Replace

 

 

Inlet valve not opening fully

Overhaul or replace

 

 

Separator element dirty or collapsed

Replace

 

 

Pipe / Hoses blocked or collapsed

Clean or replace

 

 

Cooler core blocked

Clean or replace

 

 

Minimum pressure check valve not

Overhaul or replace

 

 

functioning correctly

 

 

 

Equipment between compressor

Review system requirements

 

 

and customer measuring point

 

 

 

causing pressure drop / pressure loss

 

92IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S