Digi 90000566_H manual Set switches set switches, Used, Configure MEI settings

Models: 90000566_H

1 278
Download 278 pages 26.72 Kb
Page 208
Image 208

set switches set switches

Device support

This command is supported in ConnectPort TS MEI products only.

Purpose

Configures Multiple Electrical Interface (MEI) settings on a per-port basis,

 

and displays current MEI settings. MEI settings include the type of

 

electrical interface (EIA-232 or EIA-485), the number of differential wires

 

used for communication, and whether termination and biasing resistors are

 

used.

Required

The serial permissions associated with the "set serial" command also apply

permissions

to this command. For Digi Connect products with two or more users, to use

 

this command, permissions must be set to one of the following.

 

• For a user to display the serial settings for the line on which they are

 

logged in: “set permissions s-serial=r-self”

 

• For a user to display the serial settings for any line:

 

“set permissions s-serial=read”

 

• For a user to display and set the serial settings for the line on which

 

they are logged in: “set permissions s-serial=rw-self”

 

• For a user to display the serial settings for any line, and set serial

 

settings for the line on which the user is logged in:

 

“set permissions s-serial=w-self-r”

 

• For a user to display and set the serial settings on any line:

 

“set permissions s-serial=rw”

 

See "set permissions" on page 157 for details on setting user permissions

 

for commands.

Syntax

Configure MEI settings

 

set switches [port=range]

 

[mode={232485}]

 

[wires={twofour}]

 

[termination={onoff}]

 

Display current MEI settings

 

set switches