Digi 90000566_H manual Poweronmessage=0x followed by up to 64 hex digits, Txretries option

Models: 90000566_H

1 278
Download 278 pages 26.72 Kb
Page 89
Image 89

set bsc

power_on_message=(0x followed by up to 64 hex digits)

The status message that is sent to the host the first time a connection is established after the Digi device server has been powered on or rebooted.

 

no_response_message=(0x followed by up to 64 hex digits)

 

The status message that is sent to the host when there has been no

 

response from the bisync serial device. The message is sent after the

 

receive has timed out for the number of retries specified on the

 

“tx_retries” option.

Example

#> set bsc serial_mode=bisync3275 baudrate=2400

 

#> set bsc code_set=ascii text_con=on polling_addr=0xc1 selection_addr=0x61

 

device_id=0x40

 

#> set bsc poll_interval=1000 rx_timeout=3000 tx_retries=3

 

#> set bsc mode=client server_hostname=test.example.com server_port=8501

 

use_ssl=on

 

#> set bsc tpdu_header=on power_on_message=0x506F776572204F6e

 

#> set bsc no_response_message=0x4E6F2052657370

 

#>

 

#> set bsc state=enabled

See also

"revert" on page 61.

 

"show" on page 249.

 

• The online help for the Web user interface’s Bisync (BSC) Settings

 

page.

 

• The Cellular Family User’s Guide’s section on configuring Bisync (BSC)

 

settings.

Chapter 2 Command Descriptions

89

Page 89
Image 89
Digi 90000566_H Poweronmessage=0x followed by up to 64 hex digits, Noresponsemessage=0x followed by up to 64 hex digits